| Check fuel temperature value in display zone 1. The temperature value must be approx. ambient temperature. |
–
| If a fault is present, a constant fuel temperature of -5.4°C is displayed. |
–
| Press keys 0 and 6 for function “End output” and confirm entry with Q key. |
–
| If no realistic display appears in display zone 1 or a substitute temperature of -5.4 °C is displayed, check fuel temperature sender -G81- and wiring to sender as follows: |
|
|
Read measured value block 7 -> | 15.4°C 15.9°C 16.7°C |
|